Doosan DX140R/DX140LCR — 1. Starter Switch

1. Starter Switch A three-position starter switch is used to start or stop engine for equipment operation. O I O. Turning switch to this position turns engine "OFF" with its electrical system. In this position engine is "OFF" but interior cabin light and fuel tank transfer pump (if equipped) are functional. I. Turning switch to this position turns engine electrical system "ON". When switch is first turned "ON" the six indicator/warning lights across top of instrument panel, will light for approximately two seconds. The battery warning light and engine oil pressure warning light should remain "ON" after the other four have turned "OFF". Figure 4 FG000014 NOTE:

Preheat Indicator Light - The operation of the preheat cycle depends on coolant temperature. When the engine coolant is cold enough, the preheat indicator light will remain "ON" until engine preheat cycle is completed. The preheat cycle takes about twenty seconds to complete, and the indicator light will turn "OFF". When the light turns "OFF", engage the starter. . Moving switch to this position will crank engine. When engine starts, release key and allow it to return to "I" (ON) position. Do not operate the starter switch for more than fifteen seconds at a time. This will help prevent damage to starter. WARNING DO NOT USE STARTING FLUIDS.

The preheat system could cause the starting fluid to explode. Starting fluids should never be used. AVOID DEATH OR SERIOUS INJURY DX140R/DX140LCR Operating Controls 2-8