Komatsu — OTHER TROUBLE

OPERATION TROUBLES AND ACTIONS Problem Main causes Remedy Combustion noise occasionally make breathing sound Defective nozzle ( Replace nozzle) Abnormal noise generated (com- bustion or mechanical) Low-grade fuel being used Change to specified fuel Overheating See "Red range of engine water temperature gauge lights up" Damage inside muffler Excessive valve clearance Replace muffler ( Adjust clearance) Engine stops during operation Clogging of feed pump prefilter Replace filter cartridge ( Check, repair) Defective engine and fuel circuit 3-109