MAINTENANCE MAINTENANCE PROCEDURE 2. Remove the cover under the right side of the machine. 3. Remove plug (G) and check that the oil level is close to the bottomedge of the plug hole. If the oil level is low, remove breather (F),and add oil through the hole of breather (F) until it reaches the bottom of the hole of plug (G). 4. Check the O-ring installed to plug (G), and if it is dam- aged, replace the O-ring. 5. Install plug (G) and plug (F). Tightening torque of plug (G): 14.7 to 19.6 N•m (1.5 to 2.0 kgf•m, 10.9 to 14.5 lbft) 6. Install the cover.
Alternator And Starting Motor - Inspect The brush may be worn or the bearing may have run out of grease, so contact your Komatsu distributor for inspec- tion or repair. If the engine is started frequently, have this inspection carried out every 1000 hours. Engine Valve Clearances - Inspect Special tools are needed for inspection and maintenance, so please contact your Komatsu distributor. 4-69