ATTACHMENTS AND OPTIONS AIR CONDITIONER Off Season Checks Even during the off-season, run the compressor at low speed for 3 to 5 minutes once a month to prevent the loss of the oil film at the lubricated parts of the compressor.
Inspection and Maintenance Items Inspection and maintenance items Content of inspection and maintenance Maintenance interval guideline Refrigerant (gas) Filling quantity Twice a year; spring and autumn Condenser Clogging of fin Every 500 hours Compressor Operating condition Every 4000 hours V-belt Damage and tension Every 250 hours Blower motor and fan Operating condition (Check for abnormal sound) When required Control mechanism Operating condition (Check for normal function) When required Piping at connection Installation condition, looseness of tight- ening portion, connecting portions, gas leakage, damage When required 6-13