Komatsu — 24 VDC Solid State Timer Checkout & Adjustment

Maintenance - Section 4 OM4031.2 Page 4- 22 Automatic Lube System SYSTEM CHECKOUT To check system operation (not including timer), pro- ceed as follows: 1. Lift the passenger seat and connect a jumper wire between “SOL” terminal and “LUBE SW” terminal on the lube cycle timer or activate test switch if installed. 2. Turn keyswitch “ON” and start the engine. The pump should operate. 3. Keep system activated until the pump stalls or pressure switch closes. 4. Disconnect jumper wire or release test switch. System should vent. Turn keyswitch “OFF”. FIGURE 3-9. TIMER (TOP COVER REMOVED) 1. Timer Enclosure 2. Red LED (Light Emitting Diode) 3.

Time Selector 24 VDC TIMER CHECK To check the timer operation without waiting for the normal timer setting, proceed as follows: 1. Remove timer dust cover. NOTE: The timer incorporates a liquid and dust tight cover which must be in place and secured at all times during truck operation . 2. Adjust timer selector (3, Figure 3-9) to 5 minute interval setting. Lubrication Cycle Timer Adjustment The timer is factory set for a nominal 2.5 minute (off time) interval. Dwell time is approximately 1 minute, 15 sec- onds. A longer interval (off time) is obtained by turning the Selector knob (3, Figure 3-9) to the desired position . 3. The timer should cycle in five minutes if the truck is operating.

NOTE: If the timer check is being made on a cold start, the first cycle will be approximately double the nominal setting. All subsequent cycles should be within the se- lected time tolerance . NOTE: Set timer by turning the Selector knob (3) to the 2.5 minute setting point. Then, turn the Selector clock- wise, one detent at a time, to the desired setting, or until the maximum limit of eighty minutes is reached . 4. Voltage checks at the timer should be accomplished if the above checks do not identify the problem. a. Insure timer ground connection is clean and tight. b.

Using a Volt-Ohm meter, read the voltage be- tween positive and negative posts on the solid state timer with the truck keyswitch “ON”. Normal reading should be 18-26 VDC, depend- ing upon whether or not the engine is running. The timer is a sealed unit, do not attempt disassem- bly.