MBE 4000 SERVICE MANUAL 9. Remove the four bolts attaching the EGR control valve to the thermostat housing. See Figure 7-39. 1. EGR Control Valve Mounting Bolts 3. EGR Control Valve 2. Wiring Harness Terminal 4. EGR Temperature Sensor Figure 7-39 Removal or Installation of EGR Control Valve 10. Pull the EGR control valve out of the reed valve housing flange. 11. Remove symmetric membrane from the housing flange. See Figure 7-38. All information subject to change without notice. 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 7-47