11.3 RUNNING THE ENGINE 11.3 RUNNING THE ENGINE The following sections cover normal operations: 11.3.1 Battery Charge The battery charge indicator light must go out once the engine starts. If the indicator light comes on while the engine is running, do the following: 1. Shut down the engine. 2. Check the poly-V belt for tightness. FIRE To avoid injury from fire, keep all potential ignition sources away from diesel fuel, including open flames, sparks, and electrical resistance heating elements. Do not smoke when refueling. 3. Do a load test on the batteries. Charge or replace the batteries as needed. 4.
If necessary, visit the nearest authorized dealer to have the alternator voltage and output checked. 11.3.2 Oil Pressure When the engine has reached its normal operating temperature, the engine oil pressure must not drop below the following values: 250 kPa (36 psi) at rated speed 50 kPa (7 psi) at idling speed If oil pressure drops below these values, stop the engine and determine the cause. 11.3.3 Excessive Idling Never allow the engine to idle for more than 30 minutes. Excessive idling can cause oil to leak from the turbocharger. 11.3.4 Changing the Idle Speed The rpm range of the MBE 4000 engine is 600 to 850 rpm if the parameters in the VCU are set to the default range.
Change the idling speed as follows: All information subject to change without notice. 11-10 6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION