MBE 4000 SERVICE MANUAL A = On-highway trucks and motor coaches, city transit coaches, pickup and delivery, short trip, and emergency vehicles. B = Industrial, generator set, and other applications Table 13-9 Nitrite Interval Checks 13.1.7 Inhibitor Level Checking Use Detroit Diesel PowerTrac 3–way Coolant Test Strips to measure nitrite and glycol concentrations. Cavitation/corrosion protection is indicated on the strip by the level of nitrite concentration. Freeze/boil-over protection is determined by glycol concentration. Check the inhibitor level as follows: All information subject to change without notice.
6SE412 0403 Copyright © 2004 DETROIT DIESEL CORPORATION 13-21 Coolant Maintenance Interval Action Antifreeze/Water + SCA Inhibitor (DDC Power Cool) A. 20,000 miles (32,000 km) or 3 months B. 500 hours or 3 months Test nitrite concentration with test strip. Add SCA or dilute coolant as needed. A. 30,000 miles (480,000 km) B. 2 years or 4,000 hours Drain and clean system. Replace with new coolant. Ethylene Glycol/Water + SCA Inhibitor A. 20,000 miles (32,000 km) or 3 months B. 500 hours or 3 months Drain and clean system. Replace with new coolant. A. 300,000 miles (480,000 km) B. 2 years or 4,000 hours Drain and clean system. Replace with new coolant. Ethylene Glycol/Water + NOAT Inhibitor A.
300,000 miles (480,000 km) or 2 years B. 5,000 hours Add Power Cool Plus Extender A.600,000 miles (960,000 km) B. 4 years or 10,000 hours Drain and clean system. Replace with new coolant. Water Only + SCA Inhibitor A. 20,000 miles (32,000 km) or 3 months B. 500 hours or 3 months Drain and clean system. Replace with new coolant. A. 3000,000 miles (480,000 km) B. 2 years or 4,000 hours Drain and clean system. Replace with new coolant. Water Only + NOAT Inhibitor A. 3000,000 miles (480,000 km) or 2 years B. 5,000 hours Add Power Cool Plus Extender A. 6000,000 miles (960,000 km) B. 4 years or 10,000 hours Drain and clean system. Replace with new coolant.