Komatsu — ELECTRONIC CONTROL SYSTEM

TROUBLESHOOTING OPERATION ELECTRONIC CONTROL SYSTEM If an error code appears on the machine monitor display (normally displays TIME), follow the countermeasure table as shown below in the self-diagnosis. Machine monitor trouble display (*): For details of handling the emergency pump drive switch, swing holding brake cancel switch, and emergency work equipment actuation switch, see "SWITCHES (PAGE 3-17)".

3-132 Monitor display Error mode Countermeasure E02 PC-EPC valve sys- tem error If the pump override switch is set to the ON posi- tion, operation can be carried out.However,imme- diately have the TVC valve system inspected by your Komatsu distributor.(*) E03 Swing brake system error Turn the swing prolix switch ON to cancel the brake. When applying the swing brake, operate the swing lock switch manually. Depending on the cause of the failure, it may be impossible to release the brake.In any case, have the system inspected immediately by your Komatsu distribu- tor.(*) E05 Governor system error Governor will not execute the control function.

Manually operate the governor-lever.To fix the governor lever at the full stroke position,use the retaining bolt holes on bracket.In this case, imme- diately have the governor system inspected by your Komatsu distributor. In the case where the monitor will not display error codes and work equipment operation and swing operation can- not be carried out. Have the machine inspected immediately by your Komatsu distributor.