MAINTENANCE MAINTENANCE PROCEDURE CHECK AND ADJUST AIR CONDITIONER (ONLY MACHINES EQUIPPED WITH AIR CONDITIONER) CHECK LEVEL OF REFRIGERANT (GAS) WARNING If the refrigerant used in the cooler gets into your eyes or on your hands, it may cause loss of sight or frostbite. Do not touch the refrigerant. Never loosen any part of the refrigerant circuit. Do not bring any flame close to any point where the refrig- erant gas is leaking. If there is a lack of refrigerant (Freon 134a), the cooling perfor- mance will be poor. When operating the cooler at high speed, there should be no bubbles in the sight glass (inspection window) mounted on the condenser unit receiver. No bubbles in refrigerant flow:
Correct Bubbles in refrigerant flow (bubbles continuously pass through): Refrigerant level low Colorless, transparent: No refrigerant REMARK When there are bubbles, the refrigerant gas level is low, so contact your refrigerant dealer to have refrigerant added. If the air conditioner is run with the refrigerant gas level low, it will cause damage to the compressor. Check in off-season When not being used for a long period, operate the cooler for 3 to 5 minutes once a month to supply lubricant to each component of the compressor.
Inspection and maintenance items list for cooler Maintenance interval Twice a year; spring and autumn Every 500 hours Every 4000 hours Every 250 hours When required When required When required 4-39 Inspection and maintenance items Contents Refrigerant (gas) Filling quantity Condenser Clogging of fin Compressor Function V belt Damage and tension Blower motor and fan Function (Check for abnormal sound) Control mechanism Function (Check for normal function) Piping for connection Installation condition looseness of tightening connection portions gas leakage, damage