Komatsu — CHANGE OIL IN HYDRAULIC TANK

MAINTENANCE MAINTENANCE PROCEDURE EVERY 5000 HOURS MAINTENANCE Maintenance for every 100, 250, 500 and 1000 hours service should be carried out at the same time. CHANGE OIL IN HYDRAULIC TANK WARNING The parts and oil are still at high temperature after the engine is stopped, and may cause serious burns. Wait for the temperature to go down before cleaning the breather element in the hydraulic tank. When the oil filler cap is removed, oil may spurt out, so turn the cap slowly to release the internal pressure, then remove it carefully. NOTICE If the machine is equipped with a hydraulic breaker, the hydraulic oil will deteriorate much faster than dur- ing normal bucket operations.

For details, see "MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER (PAGE 4-19)" when carrying out maintenance. Prepare the following. Refill, capacity: 115 liters (30.38 US gal) Prepare a handle for the socket wrench set. 1. Swing the upper structure so that drain plug at the lower part of the suction tube comes to the middle of the left or right track. 2. Retract the arm and bucket cylinders to the stroke end, then lower the boom and put the bucket teeth in contact with the ground. 3. Lock the safety lock lever and stop the engine. 4. Remove the cap of oil filler (F) over the hydraulic tank. 5. Set the oil container under the drain plug under the machine.

Using the handle, remove drain plug (1) and drain the oil. Check the O-ring installed to plug (1), and if it is dam- aged, replace the O-ring. After draining the oil, tighten drain plug (1). Tightening torque: 69 ± 10 N•m (7 ± 1 kgf•m, 51 ± 7 lbft). When removing drain plug (1), be careful not to get oil on your- self. 6. Add the specified amount of engine oil through oil filler port (F). Check that the oil level is between H and L on the sight gauge. For details of the method of bleeding the air, see "CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL (PAGE 3-63)". 4-69