MACHINES READY FOR ATTACHMENTS ATTACHMENTS AND OPTIONS 7. Dismount the attachment by removing the retaining pins (2 pins). Then, mount the bucket. For the bucket mounting procedure, see "REPLACE- MENT AND INVERSION OF BUCKET (PAGE 3-99)". 8. After the bucket is mounted, check the hydraulic oil level. MOUNTING PROCEDURE 1. Remove the bucket. For bucket dismounting procedure, see "REPLACEMENT AND INVERSION OF BUCKET (PAGE 3-99)". 2. Place the attachment on a flat place, install pins (A) and (B) to the arm in that order. 3. After confirming low oil temperature, remove the blind plug from the outlet and inlet port respectively. Take care that no dust, mud etc.
adheres to the hose mousepiece portions. If O-ring is damaged, replace it with a new one. 4. Connect the hose at the attachment side. When doing this, check the direction of flow of the oil and be careful not to make any mistake. 5. Turn the rotor of the stop valve connected to the inlet and outlet piping on the arm side face toward the free side. 6. Confirm that oil level in the hydraulic oil tank is cor- rect,after mounting the attachment. 6-14