OPERATION 3.4 ELECTRONIC MONITORING AND CONTROL SYSTEM ECS TEXT DISPLAY (A), illust. Z25237 Several messages are present at the same time: The last input message is displayed. The number of all current messages is indicated by a flashing number in the second text line. Example: Fault message No. 596: Faulty monitor channel engine speed 2 *2* h: -0- Date: h: M1 1/min: Time: *3* M2 1/min: Number of present messages (flashing) These present messages can be called up with key (1) (MES- SAGE). Press key 2 (UP) or 3 (DOWN) for the display of the present messages. Call up of ”HELP” Information (HELP Texts) to a displayed message.
If additional ”HELP” information (HELP Texts) to a displayed fault message are desired, press key (4) to enter the Text mode. Then press key (3), to display the ”HELP” text. Example fault message 596: Fault No. 596: Faulty monitor channel engine speed 2 Help: The frequency converter E8.2 for engine speed 2 shows inadmissible values - Check frequency converter E8.2 and pick-up B64.2 Messages and Help texts are displayed each time in two text lines. The two next text lines can be called up by pressing key (3) ”DOWN”. The fault messages including the Help text consist of maximum 8 text lines. For return to the fault message press key (2) ”UP” until the message is displayed again.
Resetting Fault Messages of the Lubrication Systems after Repairs which have been carried out with the Engine(s) running or with the Engine(s) OFF and Main Switch Key in ON position. After repairs under the above conditions it is necessary to reset the control circuit of the concerned lubrication system by actuat- ing the rotary switch on the instrument panel for a full lube cycle. If this manually actuated lube cycle is not being carried out, the fault message ”LUBE SYSTEM FAILURE” will remain on the ECS dis- play. Resetting of the lube system control circuit can also be done by shutting down the engine(s) and switching OFF the main switch key. 113