HYDRAULIC SYSTEM Hydraulic Circuits Description cooler bypass valve (8, Figure 7-1) if the cooler is clogged. Fluid returning to tank passes through a return filter (9) in the hydraulic tank. The hydraulic system contains a pump that is made up of three vane type pumping sections. Pump section (1, Figure 7-1) supplies the boom and bucket cylinders, pump section (2) supplies the steering cylinders, and pump section (3) supplies pilot flow. Priority valve (4) and unloading valve (5) act together to form a two stage hydraulic circuit. When the steering system is not being used for steering, output from pump (2) is available to the boom and bucket circuit for faster cycle times with light loads.
When pressure in the boom and bucket circuit is high, the unloading valve (5) directs any excess steering pump (2) output to tank (6). Fluid returning to tank passes through the oil cooler (7) or passes through the The steering circuit contains a priority valve (4) that senses pressure in the steering cylinders and meters oil volume proportional to the load being sensed. The pilot pump (3) supplies pump flow to the boom and bucket controls. Pilot pump flow passes through the pilot filter (10) and the pilot control valves (11,12,13 and 14). Hydraulic Schematic A schematic for the entire hydraulic system is included at the end of Section 7. See Figure 7-116.
Mega 300-III Shop Manual HYDRAULIC SYSTEM 7-1