Engine Stop Motor When the ignition switch is in the OFF position, the engine stop motor closes the fuel cutoff lever on the injection pump to prevent fuel from reaching the engine. When the ignition switch is in the ON posi- tion, the engine stop motor opens the fuel cutoff lever on the injection pump to allow fuel to be pumped to the engine. The motion generated by the engine stop motor is sent through reduction gearing and is changed to a reciprocating motion to operate the fuel cutoff lever. stop relay (6, Figure 9-2). Current from B of (4) is present at P2 of (4). This powers terminal 87 of (6) and conducts power to 30 of (6).
This powers terminal A of (4) and this powers the stop motor (4) to rotate clockwise from the 0° position to the 180° position. This moves open the cutoff lever on the injection pump and allows fuel to be pumped to the injectors. With the ignition switch in the STOP position, power is removed from terminal ACC of the ignition switch (5). This allows terminals 30 and 87a to connect inside the stop relay (6). Battery power is present at B of (4), and is conducted to P1 of (4), and 87a of (6). This conducts power to terminal 30 of (6), A of (4), E of (4), and ground. This powers the stop motor (4) to rotate clockwise from the 180° position to the 360° position.
This moves the cutoff lever on the injection pump to the closed position, and this prevents fuel from being pumped to the injectors. Current from the batteries (1, Figure 9-2) passes through the circuit breaker (2), and fuse box (3) and powers terminal B on the stop motor (4). This results in power at P2 of stop motor (4). Terminal B on the ignition switch (5) is also powered. With the ignition switch (5) in the ON position, terminal ACC is powered. ACC conducts power to terminal 86 on the stop relay (6). This energizes the solenoid in (6) and this connects terminal 87 with terminal 30 of 9-4 ELECTRICAL SYSTEM Mega 300-III Shop Manual