daewoo — Daewoo Wheel Loader Shop Manual

Engine Intake Preheat Circuit This circuit uses a thermal switch to monitor engine temperature. The thermal switch triggers an elec- tronic preheat controller to operate only when the engine is cold. The preheat controller turns on a grid type resistance heater that is positioned between the engine air cleaner and the engine intake manifold. Warming incoming air before it enters the manifold and the cylinders greatly improves engine starting efficiency. See Figure 9-3. A pulse signal is generated at alternator terminal R as soon as engine RPM exceeds 500 RPM. The signal goes to terminal 2 on the preheat controller (7, Figure 9-3) to start the timing of the 15 second shut-off sequence.

NOTE As long as the ignition switch is in the PREHEAT position, current travels from the R1 terminal on the ignition switch to terminal 4 on the preheat con- troller (7). This causes the preheat controller to send current out of terminal (5) to the C terminal of the preheat relay (10). This causes the contacts in the relay (10) to close. This supplies power to heat the coils in the heating element (4). The contacts inside the thermal switch (9) are nor- mally open. When the temperature of the coolant drops below 10°C (50°F), the contacts close.

When the ignition key (1) is turned to the PREHEAT posi- tion, the closed contacts allow the preheat con- troller (7) to begin current flow to the heating relay (10), which controls current flow (120 amps) to the heating element (4). The preheat controller (7) also turns on the preheat complete pilot light in the oper- ator’s cab (8) after the heating element has been heated for 19 seconds. The heating element (4) will heat for 19 seconds each time the ignition key is turned to the PREHEAT position. When engine coolant temperature is above 10°C (50°F) due to ambient temperature or a warm engine, preheating engine intake air is not neces- sary.

In this case, the contacts inside the thermal switch (9) are open. This prevents current flow to the preheat relay (10) which prevents the coils in the heating element (4) from receiving power. Open contacts in thermal switch (9) also trigger the pre- heat controller (7) to send current to the preheat complete light on the gauge panel in the operator’s cab. The preheat complete light turns on immedi- ately when the ignition key is turned. The preheat controller (7) switches off current flow to the heater 15 seconds after the engine has started.

The heater stays on for 15 seconds in order to achieve more complete cylinder combus- tion, shorten the time for engine warm-up, and reduce emissions generated during the engine start cycle. 9-6 ELECTRICAL SYSTEM Mega 300-III Shop Manual