Transmission The torque converter stall ratio is 2.879:1. Transmission fluid operating pressure is 5 kg/cm 2 The machine contains a powershift transmission that has 4 forward speeds and 3 speeds in reverse. Gear changes are made by an electro-hydraulic control valve that is mounted on the transmission. Moving the gear select lever in the cab, generates an electrical signal that is transmitted to the control valve. The control valve contains solenoid valves that direct pressurized fluid to various clutches that control the forward and reverse gears. (71.5 psi). Transmission fluid temperature should be kept below 90°C (194°F).
If the transmission cut-off switch (located in the cab) is in the OFF position, pressing the machine brake pedal will cut off the electrical signal to the transmission control valve. This stops the transmis- sion from conducting engine torque to the axles. This makes it much easier to slow the machine. External Assemblies Figure 4-2 identifies external transmission assemblies. 1. Input Housing 2. Torque Converter 3. Speedometer Input Flange 4. Identification Plate 5. Oil Outlet Flange 6. Output Shaft 7. Transmission Mounting Points 8. Output Shafts 9. Dipstick 10. Oil Filter 11. Electrical Control Valve 4441 FIGURE 4-2 4-2 TORQUE CONVERTER AND TRANSMISSION Mega 300-III Shop Manual