11 Any attempt to insert a feeler gauge without first securing suffi- cient space, as described below, between the pad and the valve bridge will fail, as the pad will tilt as shown in the illustration, thus blocking the entry of a feeler gauge. Before inserting a feeler gauge, push the adjusting screw pad on the side opposite from where a feeler gauge is to be inserted, as shown in the illustration, using a flat-head screwdriver or other similar tool. This will create space necessary for the gauge to be inserted. The measurement is correct when the feeler gauge feels slightly resisted as it is inserted. The measurement is not yet correct if the feeler gauge can still be inserted smoothly.
If the measurement deviates from the standard value, adjust as follows. [Adjustment] Loosen the lock nuts and adjusting screws on the valve bridge and rocker arm. While holding the valve bridge by hand, screw in the adjusting screw until it lightly contacts the valve stem end. Then, further screw in the adjusting screw by 45 ° . 11-13