Komatsu — 4.9.3 PTO’s (PUMP DISTRIBUTOR GEARS) AND OIL RESERVOIR - CHECK OIL LEVEL

MAINTENANCE 4.9 EVERY 50 OPERATING HOURS OR WEEKLY 4.9.3 PTO’s (PUMP DISTRIBUTOR GEARS) AND OIL RESERVOIR - CHECK OIL LEVEL Legend for illustration Z 20696 (1) Oil level gauge (2) Oil filler plug (3) Breather filter (4) Oil drain plug (7) Oil collector reservoir for adapter housings of hydraulic pumps for fan drives (8) Breather filter with oil level gauge (9) Adapter housings for main hydraulic pumps (10) Oil level plugs (11) Oil filler plug with breather pipe (12) Oil drain plug PUMP DISTRIBUTOR GEARS, CHECK OIL LEVEL: 1. Unscrew level gauge (1) and wipe it clean. 2. Insert gauge (1), but DO NOT screw in, see detail (A). 3. Remove level gauge and read the oil level.

The oil level should be between the “MIN” and “MAX” mark. If necessary, add oil through filler opening (2) up to the “MAX” mark on gauge (1). NOTICE If the oil level is above the “MAX” mark, drain the oil down until the oil level is at the “MAX” mark. Too much oil in the pump distributor gear will cause aeration of the oil. 4. Insert gauge (1) and tighten securely. Remove breather filter (3). Blow out with compressed air from inside to outside and reinstall. 339