Komatsu — Clean Radiator Fins and Cooler Fins

MAINTENANCE 4. Press portion (a) (manual reverse rotation ON) of cooling fan auto reverse rotation switch (1). For additional information about the fan reverse rotation switch, see “Cooling Fan Auto-Reverse Rotation Switch” on page 2-45. 5. After the cooling fan reverse rotation pilot lamp on the machine monitor flashes, check that it lights up. At the same time, “COOLING FAN REVERSE” is displayed on the character display and the fan is set to rotate in reverse. For additional information about the pilot lamp see “Cooling Fan Reverse Rotation Pilot Lamp” on page 2-25. 6. Run the engine at high idle. 7.

Select the time for running the engine at high idle dependent on the extent of the clogging. Normal clogging: 1 to 2 minutes Excessive clogging: 2 to 3 minutes 8. When the cleaning is completed, run the engine at low idle. 9. Press portion (a) (manual reverse rotation ON) of cooling fan auto reverse rotation switch (1). 10. After the cooling fan reverse rotation pilot lamp on the machine monitor flashes, check that it goes out. The fan is set to rotate in the normal direction. 11. Run the engine at low idle for about ten seconds. 3-40 WA250-6