Komatsu — Check Air Conditioner

MAINTENANCE Check Air Conditioner If the refrigerant used in the air conditioner gets into your eyes, it may cause loss of sight; if it gets on your hands, it may cause frostbite. Do not touch the refrigerant. Never loosen any part of the refrigerant circuit. Do not bring any flame close to any point where the refrigerant gas is leaking. Check Level of Refrigerant (Gas) If the air conditioner is not cooling properly, there may be a lack of refrigerant (gas). 1. Start the engine and set the engine speed to about 1,500 rpm. 2. Press main power switch (1) of the air conditioner to turn the power ON. 3. Press fan switch (2) and set the air flow to “Hi.” 4.

Press temperature control switch (3) to set the display monitor to COOL (A). 5. Open the door and window fully. 6. Press air conditioner switch (4) to turn the air conditioner switch ON. 7. Open the engine side door on the left side of the machine. 3-48 WA250-6