Komatsu — Maintenance of Air Conditioner

SAFETY Using Compressed Air When cleaning with compressed air, there is a danger of serious personal injury caused by flying dust or particles. When using compressed air to clean the filter element or radiator, wear safety glasses, anti-dust mask, gloves, and other protective equipment. Disposal of Waste Materials Never dump waste fluids in a sewer system, on the ground, in rivers, etc. Always drain fluids from your machine into the appropriate containers. Never drain fluids directly onto the ground. Obey appropriate laws and regulations when disposing of harmful objects such as oil, fuel, filters, batteries, coolant, brake fluid, and hydraulic oil.

Critical Parts The material of these components naturally changes over time. Repeated use causes deterioration, wear, and fatigue. As a result, there is a danger that these components may fail and cause serious personal injury or death. It is difficult to judge the remaining life of these components from external inspection or the feeling when operating. These parts must be replaced at the specified interval. Replace or repair safety-critical parts if any defect is found, even when they have not reached the specified replacement time. Some of the following systems contain components that may fail under extended use: Seat belts Fuel supply and delivery hoses Hydraulic system:

main delivery hoses and tubing Hydraulic hoses: all the hoses that feed and return the hydraulic fluid to and from the work equipment For additional information, see “PERIODIC REPLACEMENT OF SAFETY CRITICAL PARTS” on page 3-21. Maintenance of Air Conditioner If air conditioner refrigerant gets into your eyes, it may cause loss of sight; if it contacts your skin, it may cause frostbite. NEVER touch the refrigerant. NEVER loosen any part of the refrigerant circuit. NEVER release any refrigerant into the atmosphere. 1-46 WA250-6