. MAINTENANCE SERVICE PROCEDURE the battery, or there is no display of the UPPER 2. 4 - 72 WHEN CHECK FROM BATTERY SIDE IS NOT FEASIBL If it is impossible t o chec k the electrol yte level f the LEVEL lin e on the side of the b attery, check as follows. Remo ve cap (1) at t rt, and he to p of the battery, look through the water filler po check the electrolyte surface.
If the electrolyte do es not r each the sle eve, add distilled r so that t he level reach es th LEVE L line) w ithout f Us e the d iagram b elow fo r reference, and chec k if the e lectrolyte reaches the bot tom of the sle After adding d istilled water, tighten cap (1) s ecurely REMARK If d istilled water is added to above the bottom o f the sleeve, use a syringe to low er the level to the bottom of the sleeve. N eutralize the removed fluid wit h baking soda (sodium bicarbonate), then fl ush it away w ith a large amount of water o r consul t your K omatsu distri butor or b attery maker .
WHEN IT IS POSSIBLE TO USE INDICATOR TO CHECK ELECTROLYTE LEVEL If it is possible to use an i ndicator to ch eck the e lectrolyte level, f ollow the instruct