Komatsu — CHANGE OIL IN HYDRAULIC TANK AND CLEAN STRAINER

. MAINTENANCE SERVICE PROCEDURE EVERY 5000 HOURS SERVICE CHANGE OIL IN HYDRAULIC TANK AND CLEAN STRAINER WARNING may cause burns. Wait for the 4 - 86 Carry out the per iodic maintenance wo rk of e very 1 00, 250, 500 an d 1000 hours of o peration a t the sa emperat temperature to g o down before s tarting t he wor When removing the oil filler cap, turn it s lowly t o releas e the internal p ressure , then remove Oil replaceme nt amount: 112 liters ( 29.59 US gal Prepare a han dle (for the socket wr ench). 1. Remove the cap of oil filler port (F) at the top of the hydrauli tank. Set a contai 2. machine's un plug (P) and and if it has a draining the The speci kgf·m, 50. Take care plug (P).

machine's un derside to catc h oil tha t is drained. R emove drain plug (P) and drain the oil. Check an O-ring installe d to Plu g (P) and if it has a scratch or damage, re place it with n ew one. Afte draining the oil, tighten drai n plug ( The speci fied tightening torque 3. Add the spec ified amount o f new a nd clean oil t hrough oil filler p ort (F). Check th at the oil l evel is b etween H and L on the sight gauge. For an oil lev el checking method, re fer to the sec tion of " CHECK OIL LEVEL IN H YDRAULI C TANK, ADD OIL (PAGE 3-57) ". Take care not to get oil o n yours elf when you remove drain