Hyundai Construction Equipment — 2.2.3 Measuring clearance between outer rotor and pump case

LUBRICATION SYSTEM 2.2 Inspecting oil pump 2.2.1 Measuring clearance between outer rotor and inner rotor Measure the clearance between the outer rotor and the inner rotor. If measured value exceeds the limit, replace the oil pump with new one. Feeler gauge Measuring clearance between outer rotor and inner rotor 2.2.2 Measuring end play of rotor and pump case Measure the end play of the rotor and the pump case. If measured value exceeds the limit, replace the oil pump with new one. Straight edge Thick feeler gauge Measuring end play of rotor and pump case 2.2.3 Measuring clearance between outer rotor and pump case Measure the clearance between the outer rotor and the pump case.

If measured value exceeds the limit, replace the oil pump with new one. Feeler gauge Measuring clearance between outer rotor and pump case 9-6 Item Standard Limit 0.13 to 0.15 mm [0.0051 to 0.0059 in.] Item Standard Limit End play of rotor and pump case 0.04 to 0.09 mm [0.0016 to 0.0035 in.] 0.15 mm [0.0059 in.] Item Standard Limit Clearance between outer rotor and case 0.20 to 0.30 mm [0.0079 to 0.0118 in.] 0.50 mm [0.0197 in.]