ELECTRICAL SYSTEM 2. Disassembling, inspecting and reassembling electrical system 2.1 Inspection before disassembling starter 2.1.1 Inspecting magnetic switch Perform the inspection as described below. If faulty, replace the magnetic switch with a new one. Switch CAUTION Do not apply current continuously for longer than 10 seconds. (1) Disconnect the connector of M terminal. (2) Pull-in test Connect the starter to the circuit as shown in the illustration. The magnetic switch is normal if the pinion springs out when the switch is turned ON. Pull-in test (3) Holding test Connect the starter to the circuit as shown in the illustration. Pull out the pinion fully by hand.
The magnetic switch is normal if the pinion does not return when it is released. Battery Starter Disconnect connector. Switch Battery Starter Holding test (4) Return test Connect the starter to the circuit as shown in the illustration. Pull out the pinion fully by hand. The magnetic switch is normal if the pinion returns immediately when it is released. Switch Battery Starter Return test 12-7