ELECTRICAL SYSTEM 2.3.5 Measuring commutator outside diameter Measure the commutator outside diameter. If the measured value is less than the limit, replace the armature with a new one. Outside diameter Measuring commutator outside diameter 2.3.6 Measuring undercut depth Measure the depth of undercutting between the commutator segments. If the measured value is less than the limit, repair or replace with a new part. Segment Undercut Mica Measuring commutator undercut depth 2.3.7 Checking armature coil (1) Inspect the armature coil using a growler. Place the armature on the growler. Hold a piece of iron plate and make it contact with the armature coil as shown in the illustration.
In this condition, rotate the armature slowly by hand. If the short circuit exists on the coil, the iron plate is attracted to the coil. If coil is not defective, the iron plate is not attracted. Growler tester Iron plate Inspecting armature coil for short circuit (2) Check that there is no continuity between the commutator and the shaft (core). If any continuity is observed, replace the armature with a new one. Inspecting insulation between commutator and shaft 12-13 Item Nominal Limit Commutator outside diameter ø32 mm [1.26 in.] 31.4 mm [1.236 in.] Item Standard Limit Undercut depth 0.4 to 0.6 mm [0.016 to 0.024 in.] 0.2 mm [0.008 in.]