Hyundai Construction Equipment — 2.3.14 Inspecting starter relay

ELECTRICAL SYSTEM 2.3.13 Inspecting magnetic switch Inspect the magnetic switch for following items. Replace the magnetic switch if it is defective. (1) Open circuit of coil Check continuity between terminal S and terminal M, also check continuity between terminal S and ground. if continuity does not exist, the coil has an open circuit. (2) Adhesion of contactor Check for no continuity between terminal B and terminal M. If continuity is found, the contactor is welded closed. Terminal S Terminal B Terminal M Inspecting magnetic switch 2.3.14 Inspecting starter relay (1) Open circuit of coil Check continuity between terminal SW and terminal L.

If continuity is not found, replace the starter relay. (2) Adhension of contactor Check for no continuity between terminal S and terminal B. If continuity is found, the contactor is welded closed. Replace the starter relay. Terminal SW Terminal S Terminal B Terminal L Inspecting starter relay 12-15