ELECTRICAL SYSTEM 2.6 Inspecting and repairing alternator 2.6.1 Inspecting stator (1) Checking continuity between lead wires. Check continuity between a pair of lead wires. Also check for no continuity between a pair of lead wires and other pairs of lead wires. If defective, replace the stator. Inspecting continuity between lead wires (2) Checking insulation between lead wire and core. Check for no continuity between each lead wire and the stator core. If continuity is found, replace the stator. Note: The core cannot be replaced as a single item. Inspecting continuity between lead wires and core 2.6.2 Inspecting rectifier Check that diodes in a rectifier function properly.
To check, measure both negative (-) and positive (+) resistance alternately twice. If both infinite negative and infinite positive resistances are observed, the diode is open- Heat sink circuited. If measured value is close to 0 Ω , the diode is short-circuited. In either case, replace the rectifier with a new one. Note: Use a wide measuring range as much as possible. The current flow during test is significantly lower than the current that normally flows in the rectifier, by which the accurate resistance may not be measured using a tester, and this tendency is noticeable if the measuring range is small. Heat sink Diode lead wire Inspecting rectifier 12-20