INSPECTION AND REPAIR OF BASIC ENGINE 2. Inspecting and repairing flywheel 2.1 Measuring flatness of flywheel Place the flywheel on a surface plate and move a dial gauge on the friction surface of the flywheel to measure the flatness. Grind the friction surface of the flywheel if the limit is exceeded. Measuring flatness of flywheel 2.2 Measuring flywheel face and radial runouts Measure the runouts of the flywheel in the installed condition. If the measured value exceeds the standard, check the bolt for looseness as well as the accumulation of foreign matter on the mounting face.
Face runout measuring point Radial runout measuring point Measuring flywheel face and radial runout 2.3 Inspecting ring gear Inspect the ring gear for a missing tooth or worn teeth, and if defects are found, replace the ring gear. 2.4 Replacing ring gear 2.4.1 Removing ring gear (1) Heat the ring gear evenly using an acetylene torch or other appropriate heat source. (2) With a rod placed on the periphery of ring gear, tap the rod with a hammer evenly around the ring gear, and remove the ring gear. Flywheel 2.4.2 Installing ring gear (1) Heat the ring gear evenly up to approx. 150°C [176°F] with an appropriate heater.
(2) Install the ring gear onto the flywheel with the no-gear- chamfering side faced to the flywheel. Note: Do not heat the ring gear excessively. Ring gear Removing ring gear 6-10 Item Standard Limit Flywheel flatness 0.15 mm [0.0059 in.] or less 0.50 mm [0.0197 in.] Item Standard Limit Flywheel face runout and radial runout 0.15 mm [0.0059 in.] or less 0.50 mm [0.0197 in.]