4.1 Guides to maintenance Maintenance Welding instructions: ! Cut off power. Wait for approx. one minute after turning off the engine starting switch key, and then disconnect the neg- ative (-) terminal of the battery. ! Do not apply more than 200 V continuously. ! Connect grounding cable within 1 m from the area to be welded. If grounding cable is connected near instruments, connectors, etc., the instruments may malfunction. ! If a seal or bearing happen to come between the welding part and grounding point, change the grounding point to avoid such parts. ! Do not use the area around the work equipment pins or the hydraulic cylinders as the grounding point. !
Remove the negative (-) terminal of the battery to stop the flow of electric current. Do not drop things inside machine: ! When opening inspection windows or the oil filler port of the tank to carry out inspection, be careful not to drop nuts, bolts, or tools inside the machine. If such things are dropped inside the machine, it will cause damage and malfunction of the machine, and will lead to fail- ure. If you drop anything inside the machine, always remove it immediately. ! Do not put unnecessary things in your pockets. Carry only things which are necessary for inspection. Dusty worksites: When working at dusty worksites, do as follows: !
Clean the radiator core frequently to avoid clogging. ! Clean and replace the fuel filter frequently. ! Clean electrical components, especially the starting motor and alternator, to avoid accumulation of dust. ! When inspecting or changing the oil, move the machine to a place that is free of dust to prevent dirt from getting into the oil. WA470-6H – VEAM946100 4-3