Komatsu — Check air conditioner

4.9 Service procedure Maintenance When required Check air conditioner Check level of refrigerant (gas) If the refrigerant of the conditioner system gets into your eyes or on your hands, it may cause loss of sight or frostbite. Do not touch the refrigerant. Never loosen any part of the refrigerant cir- cuit. Do not bring any flame close to any point where the refriger- ant gas is leaking. WARNING GK047038 GK047038 1. Start the engine and set the engine speed to approx. 1500 rpm. 2. Press main power switch (1) of the air conditioner to turn the power ON. 2 3. Press fan switch (2) and set the air flow to “Hi“. 4. Press temperature control switch (3) to set the temperature to the lowest setting.

5. Open the door and window fully. 6. Press air conditioner switch (4) to turn the air conditioner switch ON. 4 1 3 GK047039 7. Use sight glass (6) (inspection window) of receiver drier (5) to check the condition of the refrigerant gas (freon 134a) flowing in the refrigerant circuit. A: Quantity of refrigerant B: Condition of sight glass a: Proper: 6 After air conditioner switch is turned ON, few bubbles are seen and refrigerant becomes milk-white and then becomes pale milk-white. 5 b: Insufficient refrigerant: After air conditioner switch is turned ON, bubbles are seen continuously. X: Condition of refrigerant flow Y: Condition of sight glass x: There are bubbles:

Gas and liquid of refrigerant are mixed. y: There are not bubbles: All refrigerant is liquefied and transparent. z: Refrigerant is milk-white: Oil and refrigerant are separated from each other and their mixture is pale milk-white. GK038106 WA470-6H – VEAM946100 4-49