4.9 Service procedure Maintenance Every 100 hours service Clean element in air conditioner fresh air filter If compressed air is used, there is danger that dirt may fly and cause personal injury. Always wear safety glasses, dust mask, and other protective equipment. If the air conditioner has been used, the air filter should be cleaned. Stop the air conditioner before cleaning the element. Articulate the machine fully to the right before replacing the air filter element. 1. Insert the starting key into key slot (1), release the lock, loosen knob (2), and open cover (3). 2 3 1 GK038109 2. Remove element (4) and clean it. 3.
Direct dry compressed air (less than 0.69 MPa) to the ele- ment from inside along its folds, then direct it from outside along its folds and again from inside. 4 Replace the filter with a new part if the clogging cannot be removed with compressed air, or if it has been used for 1 year. 4. After cleaning, return filter (4) to its original position and close the cover. Use the starting switch key to lock the cover. Do not forget to remove the starting switch key. GK038110 REMARK If the filter becomes clogged, the air flow will be reduced, and there will be an abnormal noise from the air conditioner unit. WA470-6H – VEAM946100 4-57 WARNING WARNING