Komatsu — Lubricating

4.9 Service procedure Every 4000 hours service Maintenance 4.9.12 Every 4000 hours service Maintenance for every 50, 100, 250, 500, 1000 and 2000 hours service should be carried out at the same time. Lubricating Carry out the greasing once every two years, regardless of whether the 4000 hour interval has passed. 1. Remove mounting bolts (3) of cover (1), (2) under the machine, then remove the cover. 2. Using a grease pump, pump in grease through the grease fittings marked by the arrows. 3. After greasing, wipe off any old grease that was pushed out. 2 4.

When lubricating, stop the drive shaft so that the grease fit- ting of center drive shaft spline (1) will be as shown in the fig- ure and supply grease from under the machine. 1 3 3 At this time, the grease fitting is at the position indicated by the arrow at the circle below seen from the rear of the machine. GK047056 (1) Center drive shaft spline (1 place) View from rear of machine GK043217 (2) Front drive shaft (2 places) View from rear of machine GK043218 4-86 WA470-6H – VEAM946100