6.2 Handling torque converter lock-up Attachments, Options 6.2.2 Method of operation 1. Press the top (a) of the torque converter lock-up switch to turn it ON. a The pilot lamp inside the switch lights up. 2. When the actual speed range is 3rd or 4th in either FOR- WARD or REVERSE, the torque converter lock-up function is actuated according to the travel speed and sets to direct drive. b REMARK When the gearshift lever is at 4th in auto-shift mode, the lock-up is not actuated if the actual speed range is 3rd. The lock-up is actuated only when the actual speed range is 4th. GK038038 When the lock-up is actually actuated, the lock-up pilot lamp on the machine monitor lights up. 3.
To cancel the lock-up, press the bottom (b) of the torque converter lock-up switch to turn it OFF. The lock-up is canceled. The travel speed for actuation and cancellation of the lock-up is as shown below. GK050035 6-6 WA470-6H – VEAM946100 Lock-up Speed range FORWARD travel speed (km/h) REVERSE travel speed (km/h) Actuated Canceled Actuated Canceled 3rd 13.4 to 16.0 {12.3 to 14.7} 12.4 to 15.0 {11.4 to 13.8} 14.2 to 17.0 {13.1 to 15.7} 13.2 to 15.9 {12.2 to 14.6} 4th 20.8 to 26.0 {19.2 to 24.0} 19.8 to 25.0 {18.2 to 23.0} 22.1 to 27.6 {20.4 to 25.4} 21.0 to 26.6 {19.3 to 24.5}