9 Insert dial gauge with extension. 10 Mount dial gauge with 2 mm preload onto the valve stem or piston crown. 11 Slowly turn crankshaft in direction of rotattion of engine until the larger pointer of the dial gauge stops (TDC setting). 12 Unscrew hexagon nut (la) and withdraw TDC pulse generator (1). 13 Loosen dial gauge and mount extension with 5 mm preload onto the valve stem or piston crown. Turn scale of gauge until the large pointer is at zero. 14 Turn on crankshaft in direction of rotation until the dial gauge has moved back by the appropriate value (data in table). 15 Position fixing device 119 589 00 21 00 into the setting slide (2).
The pin on the vibration damper must engage in the groove of the fixing device (1). If the pin does not engage, adjust position of setting slide. 03 0905 - 34516