John Deere Radial Piston Pumps (3000 Series) — John Deere Radial Piston Pumps (3000 Series) User Manual

AWl;R40190 R70;070300 1196 090288 CTM-7 (5-89) 2R3 ; 105 04 110589 tODD Series (PR)-Operation and Tests CAUTION: Escaping fluid under pressure can penetrate the skin causing serious injury. Re- lieve pressure before disconnecting hydraulic or other lines. Tighten all connections before applying pressure. Keep hands and body away from pinholes and nozzles which eject fluids under high pressure. Use a piece of cardboard or paper to search for leaks. Do not use your hand. If ANY fluid is injected Into the skin, it must be surgically removed within a few hours by a doctor familiar with this type injury or gangrene may result.

105-4 ADJUST DEADHEAD (STANDBY) PRESSURE NOTE When operating or testing any hydraulic pump, it is good hydraulic systems practice to include a system relief valve set at 2070 kPa (20.7 bar) (300 psi) above deadhead pressure. IMPORTANT: Adjusting screw should be set to a mini- mum depth to prevent excessive dead- head pressure at start up. 2. Connect a 0-34 500 kPa (0-345 bar) (0-5000 psi) gauge. NOTE System pressures vaf}'. Check applications or ma- chine manual for proper deadhead pressure setting. 3. Turn adjusting screw (8) in to increase deadhead pressure. 4. Tighten lock nut (C) once deadhead pressure is set. A-Test Port (E1) B-Pressure Compensator Adjusting Screw C-Lock Nut 1.

Install an adapter to port (A). AllTractorManuals.com Litho in U.S.A.