Starting Motor C8.3 Industrial Page A-18 Section A - Adjustment, Repair, and Replacement Install To install the alternator, the alternator mounting components must be tightened in the following sequence: 1. Alternator-to-alternator bracket capscrew 2. Lower brace-to-alternator capscrew 3. Lower alternator brace-to-water pump capscrew 4. Water inlet-to-block capscrews. NOTE: The wrench size and torque value is determined by the make and model of the alternator. To install the alternator, the alternator mounting components must be tightened in the following sequence: 1. Alternator-to-alternator bracket capscrew Torque Value: 43 N•m [ 32 ft-lb ] 2.
Lower brace-to-alternator capscrew Torque Value: 24 N•m [ 18 ft-lb ] 3. Lower alternator brace-to-water pump capscrew Torque Value: 24 N•m [ 18 ft-lb ] 4. Water inlet-to-block capscrews. Torque Value: 24 N•m [ 18 ft-lb ] Starting Motor Preparatory Steps Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. Disconnect the ground cable from the battery terminal. Identify each electrical wire with a tag indicating location.
WARNING Remove Remove the battery cable from the solenoid. Remove all other wires connected to the starter.