Cummins — 4021330

C8.3 Industrial Troubleshooting Symptoms Charts Section TS - Troubleshooting Symptoms Page TS-15 Coolant Temperature Above Normal - Sea Water Cooling System Cause Correction STEP 1 Sea water inlet valve is not open or is partially ............. Check sea water inlet valve. Refer to Procedure 008-057 (Sea Water Pump) in Section 6. open OK Go To Next Step STEP 2 Sea water strainer clogged ............. Clean sea water strainer. Refer to Procedure 008-067 (Sea Water Strainer) in Section 3. OK Go To Next Step STEP 3 Sea water hose(s) collapsed ............. Check sea water system hose(s). Refer to Procedure 008-104 (Sea Water Hoses) in Section 4.

OK Go To Next Step STEP 4 Sea water pump outlet pressure is excessive ............. Determine cause of sea water system blockage. Refer to OEM service manual. OK Go To Next Step STEP 5 Sea water pump is not pumping water ............. Inspect the sea water pump impeller. Refer to Procedure 008-057 (Sea Water Pump) in Section 6. OK Go To Next Step STEP 6 Contact a Cummins® Authorized Repair Facility