Cummins — 4021330

C8.3 Industrial Troubleshooting Symptoms Charts Section TS - Troubleshooting Symptoms Page TS-53 Intake Manifold Pressure (Boost) is Below Normal Cause Correction Check for loose or damaged piping connections and missing pipe plugs. Check the turbocharger and exhaust manifold mounting. Refer to OEM service manual. STEP 1 Air intake or exhaust leaks ............. OK Go To Next Step STEP 2 Air intake or exhaust leaks ............. Inspect the air intake and exhaust systems for air leaks. Refer to teh OEM service manual. OK Go To Next Step STEP 3 Air intake system restriction is above specification ............. Check the air intake system for restriction.

Clean or replace the air filter and inlet piping as necessary. Refer to Procedure 010-058 (Air Intake Piping) in Section 6. OK Go To Next Step STEP 4 Charge air cooler is restricted or leaking ............. Inspect the charge air cooler for air restrictions or leaks. Refer to Procedure 010-027 (Charge-Air Cooler) in Section A. OK Go To Next Step STEP 5 Engine power output is low ............. Refer to the Engine Power Output Low symptom tree. OK Go To Next Step STEP 6 Contact a Cummins® Authorized Repair Facility