Troubleshooting Symptoms Charts C8.3 Industrial Page TS-60 Section TS - Troubleshooting Symptoms Lubricating Oil Sludge in the Crankcase Excessive Cause Correction Check the bulk oil supply. Drain the oil and replace with noncontaminated oil. Replace the oil filter(s). Refer to Procedure 007-002 (Lubricating Oil and Filters) in Section 5. STEP 1 Bulk oil supply is contaminated ............. OK Go To Next Step STEP 2 Coolant temperature is below specification ............. Refer to the Coolant Temperature Below Normal symptom tree. OK Go To Next Step STEP 3 Crankcase ventilation system is plugged ............. Check and clean the crankcase breather and vent tube.

Refer to Procedure 003-018 (Crankcase Breather Tube) in Section 3. OK Go To Next Step Operate the engine from a tank of high-quality fuel. Refer to Procedure 018-002 (Fuel Recommendations and Specifications) in Section V. STEP 4 Fuel grade is not correct for the application or the ............. fuel quality is poor OK Go To Next Step STEP 5 Lubricating oil does not meet specifications for ............. Change the oil and filters. Refer to Procedures 007-002 (Lubricating OIl and Filters) in Section 5. operating conditions OK Go To Next Step STEP 6 Contact a Cummins® Authorized Repair Facility