SERIES 50 OPERATOR'S GUIDE tap water is preferred. High levels of dissolved chlorides, sulfates, magnesium, and calcium in some tap water causes scale deposits and/or corrosion. These deposits have been shown to result in water pump failures and poor heat transfer, resulting in overheating. If tap water is used, the mineral content in the water must be below the maximum allowable limits listed in Table 24. Coolants Not Recommended The coolants in the following sections are not recommended for use in Detroit Diesel engines. All Antifreezes and Coolants Containing Phosphate These coolants should be avoided.
Drop out, overheating and water pump seal failures can result from the use of coolant or inhibitor packages based on phosphate. NOTICE: Do not add additional SCA to new, fully formulated antifreeze or coolant. This can result in dropout and/or the formation of deposits. Automotive Type Coolants These coolants generally contain high levels of phosphate and silicate, offer no liner pitting protection, and are not suitable for use in Detroit Diesel engines. Table 24 Satisfactory Water Limits All information subject to change without notice. (Rev.
01/04) 103 DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION Tap Water Components Maximum Allowable Parts per Million Grains per Gallon Chlorides 40 2.5 Sulfates 100 5.8 Total Dissolved Solids 340 20 Total Hardness – Magnesium and Calcium 170 10