SERIES 50 OPERATOR'S GUIDE Table 25 Required Coolant Inhibitor Test Intervals Supplemental Coolant Additives for Fully Formulated Coolant The concentrations of some inhibitors will gradually deplete during normal engine operation. SCAs replenish the protection for cooling system components. The coolant must be maintained with the proper concentration of SCA. Detroit Diesel Power Cool maintenance SCAs are recommended. The proper application of SCA will provide: NOTICE: Failure to properly maintain coolant with SCA can result in damage to the cooling system and its related components. Conversely, over-concentration of SCA inhibitor can result in poor heat transfer, leading to engine damage.
Always maintain concentrations at recommended levels. Do not use traditional SCAs with OAT coolant. pH control. Restored inhibitor levels to prevent corrosion. Water softening to deter formation of mineral deposits. Cavitation protection to protect wet sleeve cylinder liners. All information subject to change without notice. (Rev.
01/04) 105 DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION Service Application Inhibitor Test Interval On-Highway Trucks and Motor Coaches 20,000 Miles (32,000 Kilometers) City Transit Coaches, Pick-Up and Delivery, Short Trip, and Emergency Vehicles 6,000 Miles (9,600 Kilometers) or 3 Months, whichever comes first Industrial, Continuous– Duty Generator Set and All Other Applications, except Standby Generator Set 500 Hours or 3 Months, whichever comes first Stand-By Generator Set 200 Hours or Yearly, whichever comes first