HOW-TO SECTION SCA Test Procedures 1. Dip the strip into coolant for one second. Remove and shake briskly to eliminate excess fluid. Detroit Diesel Power Trac 3–Way Coolant Test Strips should be used to measure nitrite and glycol concentrations. Part numbers are Listed in Table 46. Cavitation/corrosion is indicated on the strip by the level of nitrite concentration. Freeze/boil over protection is determined by glycol concentration. 2. Immediately compare the pad end (% glycol) to the color chart on the container. 3. Sixty seconds (one minute) after dipping, compare the nitrite pad to the color chart. 4.

Color change of the additive indicator (middle pad) indicates the presence of inhibitor that is not approved by Detroit Diesel. Promptly replace and tighten the test strip container cap after each use. Discard unused strips if they have turned light pink or tan. To avoid scalding from the expulsion of hot coolant, never remove the cooling system pressure cap while the engine is at operating temperature. Wear adequate protective clothing (face shield, rubber gloves, apron, and boots). Remove the cap slowly to relieve pressure. HOT COOLANT A factory coolant analysis program is available through authorized Detroit Diesel service outlets.

Part numbers are listed in Table 46 in the Specifications section. To verify coolant acceptability, submit a sample for coolant analysis every three (3) years, 300,000 miles (480,000 km), or 6,000 operating hours, whichever comes first. For best results make the test while the coolant is between 50 – 140 °F (10.0 – 60 °C). Wait at least 60, but not longer than 75, seconds before reading the nitrite level. Use the test strips as follows: 108 All information subject to change without notice. (Rev. 01/04) DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION