HOW-TO SECTION 4. Stop the engine and allow it to cool. If the engine overheats and the coolant level is satisfactory, the cooling system may require cleaning with a descaling solvent and backflushing. Authorized Detroit Diesel service outlets are properly equipped to perform these services. NOTICE: 5. With the engine cool, drain the cooling system completely. 6. Refill the cooling system with clean, soft water and operate it for fifteen minutes. 7. Stop the engine and allow it to cool. 8. With the engine cool, drain the cleaner residue from the cooling system.
In addition to the cleaning procedure, other components of the cooling system should be checked periodically to keep the engine operating at peak efficiency. 9. Refill the system with the required coolant. Refer to section How to Select Coolant. 10. Entrapped air must be purged after filling the cooling system. To do this, allow the engine to warm up without the pressure cap installed. With the transmission in neutral, increase engine speed above 1000 RPM and add coolant as required. Install the pressure cap after the coolant level has stabilized at the bottom of the radiator filler neck. Hoses.
Cooling system hoses should be inspected and any hose that shows obvious signs of damage or feels abnormally soft or hard should be replaced. Damaged clamps should also be replaced. All external leaks should be corrected as soon as detected. NOTE: If Detroit Diesel Power Cool antifreeze/coolant (or equivalent fully formulated, precharged antifreeze) is used, a precharge element is not required. Coolant inhibitor levels must be checked at the intervals listed in Table 25. 114 All information subject to change without notice. (Rev. 01/04) DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION