SERIES 50 OPERATOR'S GUIDE Preventive Maintenance Intervals Item 1 Lubricating Oil Check the oil level daily with the engine stopped. If the engine has just been stopped and is warm, wait approximately 20 minutes to allow the oil to drain back into the oil pan before checking. Add the proper grade of oil to maintain the correct level on the dipstick. See Figure 10. The following is intended as a guide for establishing preventive maintenance intervals. The recommendations given should be followed as closely as possible to obtain long life and optimum performance from your engine. Maintenance intervals indicated are time (hours) of actual operation.
The intervals shown apply only to the maintenance functions described and should be coordinated with other regularly scheduled maintenance. The “Daily” instructions apply to routine or daily starting of the engine. They do not apply to a new engine or one that has been operated for a considerable period of time. Figure 10 Check Oil Level Daily NOTICE: For new or stored engines, refer to Section 13.1, “Preparations for Starting the Engine the First Time,” in the Series 50 Service Manual (6SE50). When adding lubricating oil, do not overfill. Oil may be blown out through the crankcase breather if the crankcase is overfilled.
Preventive maintenance other than the “Daily” checks should be performed by authorized Detroit Diesel service outlets. These outlets have the trained personnel and special tools to properly perform all services. All diesel engines are designed to use some oil, so the periodic addition of oil is normal. See Figure 11 to determine the degree of oil usage. All information subject to change without notice. (Rev. 01/04) 63 DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION