MAN — MAN Series 50 Operator's Guide

SERIES 50 OPERATOR'S GUIDE Item 24 – Thermostats and Seals used in the closed crankcase breather system should be replaced every 4000 operating hours. It is not reusable and no attempt should be made to clean or reuse it. See Figure 20. Replace the thermostats and seals every 240,000 miles (384,000 km) on vehicle engines. On non-vehicle engines, replace the thermostats and seals every 4,000 hours or 24 months, whichever comes first.

Item 25 – Crankcase Breather The internally mounted (in the engine rocker cover) crankcase breather assembly should be removed and the steel mesh pad washed in clean fuel oil every 100,000 to 120,000 miles (160,000 to 192,000 km) on vehicle engines or every 1,000 hours of operation on non-vehicle engines. This cleaning period may be reduced or lengthened according to the severity of service. See Figure 19). Figure 20 Rocker Cover-Mounted Breather Item 26 – Engine Tune-Up There is no scheduled interval for performing an engine tune-up. However, the valve lash and injector heights must be measured and, if necessary, adjusted at the initial interval listed in Table 19.

Once the initial measurements/adjustments have been made, any adjustments beyond this point should be made only as required to maintain satisfactory engine performance. Figure 19 Internal (in Rocker Cover) Breather Location Item 27 – Vibration Damper The viscous vibration damper should be inspected periodically and replaced if dented or leaking. See Figure 21. The rocker cover-mounted breather assembly (part number 23512984) All information subject to change without notice. (Rev. 01/04) 81 DDC-SVC-MAN-0058 Copyright © 2004 DETROIT DIESEL CORPORATION