Komatsu — EVERY 1000 HOURS MAINTENANCE

. MAINTENANCE MAINTENANCE PROCEDURE MAINTENANCE MAINTENANCE PROCEDURE 4. Loosen water drain plug (4) to completely drain fuel in the casing. 4 - 74 5. If f uel is not drained , remove air intak e plug (5). ( Width across flats: 14 mm) 6. Disconnect drain h 7. Loosen ring nut (6) to remove casing (7). 8. Remove screen (8) from the water separator tabl e, pulling the screen out downwa rd. ith clean fuel. 9. Wash screen (8) w At that time, also ch eck it for damage and if any, r eplace it with a new one. 10.

Wash the interior o f casing (7) for damage, a cra ck or so bad a contamination as to make it impossible to identify the location of float (9), and if a ny of them is found , replace th e casing with a new one. n the water separator table. ) with a new one. n plug (4). 11. Install screen (8) o 12. Replace O-ring (10 13. Screw in water drai Tightening torque: 1.5 - 2.5 Nm (0.15 - 0.25 kgm, 1.1 - 1.8 lbft) 14. Pu t float (9) in casi ng (7) the way it does not tilt, a nd then pour clean fuel in the ca sing calmly. 15. Install casing (7) on the water separator table and tighten ring nu t (6). Tightening torque: 16 - 20 Nm (1.6 - 2 .0 kgm, 11. 6 - 14.5 lbft)