G420E/G424E Tier LP Engine Basic Troubleshooting 43 Problem Probable Cause Corrective Action Excessive Fuel Consumption/LP G Exhaust Smell Air/Fuel Mixer malfunction Check mixer z See Chapter 8 Air/Fuel mixer section Air filter clogged Check air filter z Clean/replace as required Vacuum leak Check system vacuum hoses from regulator to FTV and mixer z Repair/replace as necessary Pressure regulator malfunction/fuel pressure too high Test pressure regulator operation z See Chapter 9 Tests and Adjustments Faulty FTV Check FTV for housing cracks or obstructions z See Chapter 5 Advanced Diagnostics FTV operation z Repair and/or replace as necessary Weak ignition and/or spark control See Chapter 5 Advanced Diagnostics Incorrect air/fuel control See Chapter 5 Advanced Diagnostics Exhaust system leaks Repair exhaust system Oxygen sensor failure Replace as necessary z See Chapter 5 Advanced Diagnostics