Table a. MI-04 Diagnostic Fault Codes (Flash Codes) G420E/G424E Tier LP Engine Advanced Diagnostics 59 DFC Probable Fault Action Corrective Action, First Check 74 O2SensorSwitching O2 sensor is not switching across the reference AFR voltage Stored Fault Code (MIL, Disable Adaptive learns) Check the FTV for proper operation z Check FTV Hose Connections Check FTV for an open coil by disconnecting the FTV connector and measuring the resistance (~26Ω +/-2Ω) FTV PIN A (SIGNAL) TO PIN B (PWR) Note: If LP-Gas fuel in LP tank is not enough, this fault code can be set. If LP tank is frozen, this fault code can be set, too. It is not system trouble.
77 OxygenSensorInputHigh O2 sensor SECM driver signal is shorted to power Stored Fault Code (MIL, Disable Adapts) Check if O2 sensor is shorted to +5VDC or Battery. O2 (SIGNAL) PIN B to SECM PIN 3 (AFRTrimValveLowerDC fault should also occur) Verify O2 sensor heater circuit is operating by measuring circuit resistance (2.1Ω +/-0.4Ω) O2 PIN C (HEATER GND) to PIN D (HEATER PWR)